33
Dual-pressure regulator
Notes
The dual-pressure regulator is
not a complete safety solution. It
can be used as part of a solution.
Special features
Diaphragm pressure regulator
with secondary venting for
setting two different initial
pressures in one device.
Switching from the lower to the
higher value occurs electrically.
Technical data
Regulator pressure P2
0.5 ... 7 bar
Supply pressure P1
1.5 ... 10 bar
Flow rate
up to 1300 l/min
Temperature range
-10 ... +60°C
M
Q
Part no.
Type
550588
LR-D-MINI-ZD-V24-SA
567841
LR-D-MINI-ZD-V24-UK-SA
Safety function
Reducing pressure and force
Please observe the legal information on page 73.
L
L
Cat.
PL
DC
Channels
1
Safety component
No
to MD 2006/42/EC
All specified values are
maximum values,
which can be achieved
via correct operation
and interconnection
of the SRP/CS.
Can be used in
higher category
systems.